PWX_J1 connector

J1 connector pin arrangement
PIN NoSignal nameDescription
1STATUS COMStatus signal common for pins 2, 3, and 14 to 16.
2CV STATUSOn when the PWX series is in CV mode (open-collector output from a photocoupler).*1
3CC STATUSOn when the PWX series is in CC mode (open-collector output from a photocoupler).*1
4N.C.Not connected.
5ALM CLRAlarm clear terminal.
Alarms are cleared when a low TTL level signal is applied to this terminal.
6SHUT DOWNOutput shutdown control terminal. The output is turned off when a low TTL level signal is applied to this terminal.
7PRL IN-Negative input terminal for master-slave parallel operation.
8PRL IN+Positive input terminal for master-slave parallel operation.
9PRL COMP INCorrection signal input terminal for master-slave parallel operation.
10A COMExternal signal common for pins 5 to 9, 11 to 13, 20 to 22, 24, and 25.
During remote sensing, this is the negative electrode (-S) of sensing input. When remote sensing is not being performed, this is connected to the negative output.
11PRL OUT+Positive electrode output terminal for master-slave parallel operation.
12PRL COMP OUTCorrection signal output terminal during Master-slave parallel operation
13I SUMCurrent signal terminal for master-slave parallel operation.
14ALM STATUSOn when a protection function (OVP, OCP, OHP, FAN, SEN, or AC_FAIL) has been activated or when an output shutdown signal is being applied (output through an open-collector photocoupler).*1
15PWR ON STATUSOutputs a low level signal when power is turned on (CF11: 0) or when power is turned off
(CF11: 1; output through an open-collector photocoupler).*1
16OUT ON STATUSOn when output is on.
(CF11: 1; output through an open-collector photocoupler).*1
17N.C.Not connected.
18OUT ON/OFF CONTOutput on/off terminal.
On (or off) when a low (or high) TTL level signal is applied.
19A COMExternal signal common for pins 5 to 9, 11 to 13, 20 to 22, 24, and 25.
During remote sensing, this is the negative electrode (-S) of sensing input. When remote sensing is not being performed, this is connected to the negative output.
20REF OUTExternal resistance control terminal
5.25 V (CF07: Lo) or 10.5 V (CF07: Hi).
21I PGMTerminal used to control the output current with an external voltage or external resistance.
0 V to 5 V; 0 % to 100 % of the rated output current (CF07: Lo).
0 V to 10 V; 0 % to 100 % of the rated output current (CF07: Hi).
22V PGMTerminal used to control the output voltage with an external voltage or external resistance.
0 V to 5 V; 0 % to 100 % of the rated output voltage (CF07: Lo).
0 V to 10 V; 0 % to 100 % of the rated output voltage (CF07: Hi).
23A COMExternal signal common for pins 5 to 9, 11 to 13, 20 to 22, 24, and 25.
During remote sensing, this is the negative electrode (-S) of sensing input. When remote sensing is not being performed, this is connected to the negative output.
24I MONOutput current
0 % to 100 % of the rated output current is generated as a voltage between 0 V and 5 V (CF08: Lo) or a voltage between 0 V and 10 V (CF08: Hi).
25V MONOutput voltage monitor
0 % to 100 % of the rated output voltage is generated as a voltage between 0 V and 5 V (CF08: Lo) or a voltage between 0 V and 10 V (CF08: Hi).

*1 Open collector output: Maximum voltage of 30 V and maximum current of 8 mA.
The status common is floating (isolation voltage of 60 V or less), it is isolated from the
control circuit.