AC Hipot Tester

TOS5300

TOS5300

220,000 (税込:242,000

  • Replacement model: TOS5200
  • The PWM amp system provides highlystable output
  • AC withstand voltage test of 5 kV/100 mA (500 VA)
  • High accuracy measurements of ±1.5% of reading (at 500V or more for voltmeter and 1mA or more for ammeter)
  • Rise/fall time control
  • Key lock & actuator cover
  • Equipped with USB interface

This product generates high voltage! The use of this product requires knowledge of electricity.Improper handling or operation of this product can be very dangerous, so be sure to read the instruction manual carefully and use this product properly.


SKU: TOS5300

製品概要

常に安定した出力でAC耐電圧試験を実現!(入力電圧変動率±0.3%)

一般的な耐電圧試験器は、ACラインの入力電圧をスライドトランスを使い昇圧して出力しています。このスライドトランス方式では入力電圧の変動が出力に影響するため、正しく試験できないことがあります。歪んだ電圧を被試験物に印加する事は新品不良の原因を作ってしまう(部品劣化の加速)場合もあるのです。TOS5300シリーズは高効率PWMアンプを内蔵しており、ACラインの変動に影響を受けない安定した高電圧を出力できますので、電圧変動の大きい地域でも『安心』して、『安定』した信頼性の高い『安全』な試験が可能です。

TOS5300 image

高精度・高分解能・高速判定を実現

電圧計は±1.5% of reading(500V以上)/最小分解能1V、電流計は±1.5% of reading(1mA以上)/最小分解能1μAと高確度・高分解能のTr ue RMS計測回路を搭載しています。また、オートレンジ機能を搭載し、下限判定確度も上限判定確度と同等の性能を実現したため、テストリードの未接続や接触不良などが有効に検出できるようになりました。さらに試験時間0.1秒の高速判定を実現。高精度・高分解能・高速計測・判定機能で確実な試験を行うことが出来ます。

生産現場での誤操作を防止するパネルカバー

電子機器の生産ラインや検査ラインのワーカーは専門技術者ではないケースが多く、知らずに設定を変更してしまったり、誤操作をしてしまう可能性が高いです。これを防止するため、キーロック機能を装備するとともに、パネルを物理的に操作できなくするカバーを設けました。

ワールドワイド対応

TOS5300入力電源変更することなく海外工場でもそのまま使用できます。また、出力周波数が選択できるので、入力側の電源環境に依存しません。周波数50Hz╱60Hzの安定した試験電圧を供給します。

タクトタイムを短縮

タクトタイムの短縮は生産性の向上につながります。タクトタイムを短くする事=測定の応答速度より早い試験時間では測定確度を極端に悪くしてしまうことから、耐電圧試験の命題でしたが、TOS5300シリーズでは0.1秒からの設定が可能になりました。

安全性と機能性を高めた出力端子

実際に使用される現場の環境およびオペレータの安全に配慮し、HIGH側出力端子を操作部から一番遠い所に配置しました。回転機構によりケーブルのねじれ(断線)を防止します。一方のLOW端子もロック機構を本体側に持たせる事でLOW側テストリードの金具を廃止しテストリードが傷つきにくくなりました。これら出力端子の突起部を無くす事により移動時などによる不意の破損を防止することが出来ます。また万一、被試験体と接続ケーブルが何かに引っ掛かったり、不用意な外力が加わった場合はHIGH(高圧)側は外れやすく、LOW(接地)側は外れにくい構造となっています。誤挿入を防ぐためHIGH(赤)、LOW(黒)の色分けはもとより、端子形状も異なるものにしました。

TOS5300

仕様

耐電圧試験器部

Open in a new windowZOOM

Item/ModelTOS5300TOS5301TOS5302
AC Output sectionOutput range 0.05 kV to 5.00 kV
Accuracy± (2 % of set + 20 V) when no load is connected
Selectable range0.00 kV to 5.50 kV
Resolution10 V STEP
Max. rated output *1500 VA (5 kV/100 mA)
Max. rated voltage5 kV
Max. rated current100 mA (when the output voltage is 0.5 kV or greater)
Transformer rating500 VA
Output voltage waveform *2 Sine
DistortionIf the output voltage is 0.5 kV or more: 3 % or less (when no load or a pure resistive load is connected)
Frequency 50 Hz or 60 Hz
Accuracy±0.5 % (excluding during voltage rise time)
Voltage regulation10 % or less (when changing from maximum rated load to no load)
Input voltage variation±0.3 % (5 kV when no load is connected; power supply voltage: 90 V to 250 V)
Short-circuit current200 mA or more (when the output voltage is 1.0 kV or greater)
Output methodPWM switching
DC output sectionOutput range 0.05 kV to 6.00 kV
Accuracy±(2 % of set + 20 V) when no load is connected
Selectable range0.00 kV to 6.20 kV
Resolution10 V STEP
Max. rated output *150 W (5 kV/10 mA)
Max. rated voltage6 kV
Max. rated current10 mA
Ripple(TYP)5 kV when no loadisconnected50 Vp-p
Max. rated load100 Vp-p
Voltage regulation3 % or less (when changing from maximum rated load to no load)
Short-circuit current (TYP)40 mA (when generation 6 kV output)
Discharge featureForced discharge after test completion
(discharge resistance: 125 kΩ)
Start voltageThe voltage at the start of withstanding voltage tests can be set to 50% of the test voltage.
Limit voltageThe test voltage upper limit can be set . AC: 0.00 kV to 5.50 kV, DC: 0.00 kV to 6.20 kV
Output voltage monitor featureIf output voltage exceeds the specified value + 350 V or is lower than the specified value – 350 V, output is turned off, and protective features are activated.
VoltmeterAnalogScale6 kV AC/DC f.s
Accuracy±5 % f.s
IndicationMean-value response/rms scale
DigitalMeasurement range0.000 kV to 6.500 kV AC/DC
Display□ . □□□ kV
AccuracyV < 500 V: ±(1.5 % of rdng + 20 V); V ≥ 500 V: ±1.5 % of rdng
Response*3True rms/ Mean-value response rms display Can be switched
Hold featureAfter a test is finished, the measured voltage is retained until the PASS or FAIL judgment is cleared.
AmmeterDigitalMeasurement rangeAC:0.00 mA to 110 mAAC:0.00 mA to 110 mA
DC: 0.00 mA to 11 mA
AC:0.00 mA to 110 mA
Displayi = measured current
i < 1 mA:□ . □□□ mA
1 mA ≦ i < 10 mA:□ . □□□ mA
10 mA ≤ i < 100 mA
100 mA ≦ i:□□□ . □ mA
Accuracy*41.00 mA ≤ i: ±(1.5 % of rdng); i < 1.00 mA: ±(1.5 % of rdng + 30 μA)
Response*3True rms/ Mean-value response rms display Can be switched
Hold featureAfter a test is finished, the measured voltage is retained until the PASS judgment is cleared.
Judgment featureJudgment method and judgment operation
JudgmentJudgment methodDisplayBuzzerSIGNAL I/O
UPPER FAILIf a current that is greater than or equal to the upper limit is detected, the output is turned off, and an UPPER FAIL judgment occurs.FAIL LED lights
OVER is displayed on the screen
ONGenerates a U-FAIL signal
LOWER FAILIf a current that is less than or equal to the lower limit is detected, the output is turned off, and a LOWER FAIL judgment occurs. This judgment is not performed during voltage rise time (Rise Time) of all tests and during the voltage fall time (Fall Time) of AC withstanding voltage tests.FAIL LED lights
UNDER is displayed on the screen
ONGenerates a U-FAIL signal
PASSIf the specified time elapses without any problems, the output is turned off, and a PASS judgment occurs.PASS LED lights
displayed on the screen
ONGenerates a PASS signal
  • If PASS HOLD is enabled, the PASS signal is generated continuously until the TOS5300 Series receives a STOP signal.
  • The UPPER FAIL and LOWER FAIL signals are generated continuously until the TOS5300 Series receives a STOP signal.
  • The FAIL and PASS buzzer volume levels can be changed.
  • For PASS judgments, the length of time that the buzzer sounds for is fixed to 0.2 seconds. Even if PASS HOLD is enabled, the buzzer turns off after 0.2 seconds.
Upper limit settingAC: 0.01 mA to 110 mAAC: 0.01 mA to 110 mA
DC: 0.01 mA to 11 mA
AC: 0.01 mA to 110 mA
Lower limit settingAC: 0.01 mA to 110 mA / OFFAC: 0.01 mA to 110 mA / OFF
DC: 0.01 mA to 11 mA / OFF
AC: 0.01 mA to 110 mA / OFF
Judgment accuracy *41.00 mA ≤ i: ±(1.5 % of set), i < 1.00 mA: ±(1.5 % of set + 30 μA)
Current detection methodCalculates the current’s true rms value and compares this value with the reference value
CalibrationCalibrated with the rms of a sine wave using a pure resistive load
TimeVoltage rise time 0.1 s to 10.0 s
Resolution0.1 s
Voltage fall time0.1 s / OFF (only enabled when a PASS judgment occurs)
Test Time 0.1 s to 999 s, can be turned off (TIMER OFF)
Resolution0.1 s to 99.9 s: 0.1 s0 / 100 s to 999 s: 1 s
Accuracy± (100 ppm + 20 ms)
AC: Excluding Fall Time
DC: Rise Time Add ±50 ms at 1 kV or more, Add ±100 ms at less than 1kV.

*1. Regarding the output time limits: Taking size, weight, and cost into consideration, the heat dissipation capability of the voltage generator that is used for withstanding voltage tests has been designed to be one half that of the rated output. Use the TOS5300 Series within the following limits. If you use the product in a manner that exceeds these limits, the output section may overheat, and the internal protection circuits may be activated. If this happens, stop testing, and wait until the TOS5300 Series returns to its normal temperature.

Ambient temperatureUpper limit settingPause timeOutput time
t ≤ 40 °CAC50 mA < i ≤ 110 mAGreater than or equal to the output time30 min. max.
i ≤ 50 mANot necessaryContinuous output possible
DC5 mA < i ≦ 11 mAGreater than or equal to the output time1 min. max.
i ≦ 5 mAGreater than or equal to the wait time (WAIT TIME)Continuous output possible

(Output time = voltage rise time + test time + voltage fall time)

*2. Regarding the test voltage waveform: Waveform distortions may occur if an DUT whose capacitance is dependent on voltage (for example, an DUT that consists of ceramic capacitors) is connected as the load. However, if the test voltage is 1.5 kV, the effect of a capacitance of 1000 pF or less can be ignored. Because the product’s high-voltage power supply uses the PWM switching method, if the test voltage is 500 V or less, the switching and spike noise proportions are large. The lower the test voltage, the greater the waveform is distorted. *3.For both True rms and Mean-value response, 50 ms or above response time is required to satisfy the measurement accuracy. *4. Regarding ammeter and judgment accuracy: During AC withstanding voltage tests, current also flows in the stray capacitance of items such as the measurement leads and jigs. This current that flows in the stray capacitances is added to the current that flows in the DUT, and the sum of these currents is measured. Especially if you want to perform judgments with high sensitivity and accuracy, it is necessary to consider methods to limit the current that flows in these stray capacitances, such as by adding upper and lower limits.

Output voltage1 kV2 kV3 kV4 kV5 kV
When using 350 mm long test leads that are suspended in air (TYP)2 μA4 μA6 μA8 μA10 μA
When using the accessory, high test lead TL31-TOS (TYP)16 μA32 μA48 μA64 μA80 μA
その他の機能/インターフェース

Open in a new windowZOOM

Item/ModelTOS5300TOS5301TOS5302
Double action featureTests can only be started by pressing and releasing STOP and then pressing START within 0.5 seconds of releasing the STOP switch.
Length of time to maintain a PASS judgment resultYou can set the length of time to maintain a PASS judgment: 50 ms, 100 ms, 200 ms, 1 s, 2 s,5 s, or HOLD.
Momentary featureTests are only executed while the START switch is held down.
Fail mode featureThis feature enables you to prevent remotely transmitted stop signals from clearing FAIL judgments and PROTECTION modes.
Timer featureThis feature finishes tests when the specified time elapses.
Output voltage monitor featureIf output voltage exceeds “setting + 350 V” or is lower than “setting – 350 V,” the TOS5200 switches to PROTECTION mode, output is turned off, and testing finishes.
MemoryUp to three sets of test conditions can be saved to memory.
Key lockLocks panel key operations (settings and changes).
Protective features Under any of the following conditions, the TOS5300 Series switches to the PROTECTION state, immediately turns output off, and stops testing. A message is displayed on the screen.
Interlock ProtectionAn interlock signal has been detected.
Power Supply ProtectionAn error was detected in the power supply.
Volt Error ProtectionWhile monitoring the output voltage, a voltage outside of the rated limits was detected. AC or DC withstanding voltage tests: ±350 V Insulation resistance test: ±(10 % of set + 10 V)
Over Load ProtectionDuring a withstanding voltage test, a value that is greater than or equal to the output limit power was specified. AC withstanding voltage test: 550 VA. DC withstanding voltage test: 55 VA.
Over Heat ProtectionThe internal temperature of the TOS5200 became too high.
Over Rating ProtectionDuring a withstanding voltage test, the output current was generated for a length of time that exceeds the regulated time.
Calibration ProtectionThe specified calibration period has elapsed.
Remote ProtectionA connection to or disconnection from the front- panel REMOTE connector was detected.
SIGNAL I/O ProtectionThe rear-panel SIGNAL I/O connector’s ENABLE signal has changed.
USB ProtectionThe USB connector has been disconnected while the TOS5300 Series was being controlled through the USB interface.
System clock Set in the following format: year/month/day hour/minutes/seconds.
Calibration dateSet when the TOS5300 Series is calibrated.
Calibration period settingSets the period before the next calibration is necessary.
Notification of when the calibration period elapsesSets the operation that is performed when the specified calibration period elapses. When the TOS5300 Series turns on, it can display a notification or switch to the protection mode and disable testing.
InterfaceUSBUSB Specification 2.0
REMOTEFront-panel 9-pin MINI DIN connector. By connecting an optional device to this connector, you can control the starting and stopping of tests remotely.
SIGNAL I/ORear-panel D-sub 25-pin connector
一般仕様

Open in a new windowZOOM

Item/ModelTOS5300TOS5301TOS5302
DisplayVFD: 256 × 64 dots + 4 status indicators
Backup battery life3 years (at 25 °C or 77 °F)
EnvironmentInstallation locationIndoors, at a height of up to 2000 m
Spec guaranteed range temperature/ humidity5 °C to 35 °C (41 °F to 95 °F)/20 %rh to 80 %rh (no condensation)
Operating range temperature/ humidity0 °C to 40 °C (32 °F to 104 °F)/20 %rh to 80 %rh (no condensation)
Storage range temperature/ humidity-20 °C to 70 °C (-4 °F to 158 °F)/90 %rh or less (no condensation)
Power supplyNominal voltage range (allowable voltage range)100 VAC to 240 VAC (90 VAC to 250 VAC)
Power consumptionWhen no load is connected (READY)100 VA or less
When rated load isconnected800 VA max.
Allowable frequency range47 Hz to 63 Hz
Insulation resistance (between AC LINE and the chassis)30 MΩ or more (500 VDC)
Withstanding voltage (between AC LINE and the chassis)1400 VAC, 2 seconds (Routine test) / 1500 VAC, 1 minutes (Type test)
Earth continuity25 AAC, 0.1 Ω or less
Safety*1Complies with the requirements of the following directive and standard.
Low Voltage Directive 2014/35/EU,EN 61010-1 (Class I *5 , Pollution degree 2 *6 )
Electromagnetic compatibility *1*2Complies with the requirements of the following directive and standard.
EMC Directive 2014/30/EU, EN 61326-1(Class A*3), EN 55011(Class A*3, Group1*4)
EN 61000-3-2, EN 61000-3-3
Applicable under the following conditions
The maximum length of all cabling and wiring connected to the TOS5200 must be less than 2.5 m.
The shielded cable is being used when using the SIGNAL I/O.
The high-voltage test lead TL31-TOS is being used.
Electrical discharges are not occurring outside the DUT
Outline drawing320 (12.6″) (330(12.99″)) W × 132(5.2″) (150(5.91″)) H × 350(13.78″) (420(16.54″)) D
WeightApprox. 14 kg (30.9 lbs)Approx. 15 kg (33.1 lb.)Approx. 14 kg (30.9 lbs)
AccessoriesPower cord : 1pc. / High test lead (TL31-TOS) : 1set (1 red wire and 1 black wire, each with alligator clips); 1.5 m / D-sub 25-pin plug : 1set ; assembly type / High-voltage warning sticker : 1pc. / User’s manual : 1pc. / CD-R : 1pc.

*1 Does not apply to specially ordered or modified TOS5300s. *2 Limited to products that have the CE mark/UKCA mark on their panels. Not be in compliance with EMC limits unless the ferrite core is attached on the cable for connection of J1 connector. *3 This is a Class A equipment. The TOS5300 is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts. *4 This is a Group 1 equipment. The TOS5300 does not generate and/or use intentionally radio-frequency energy, in the from of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose. *5 This is a Class I equipment. Be sure to ground the TOS5300’s protective conductor terminal. The safety of this product is only guaranteed when the product is properly grounded. *6 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2

オプション

耐電圧試験器用 高電圧テストリード

リモートコントロール・ボックス

注:TOS5200でのご使用には、リモコン用変換ケーブル(DD-5P/9P)も合わせてお求めください。

耐電圧試験器用 高電圧テストプローブ

注:TOS5200でのご使用には、リモコン用変換ケーブル(DD-5P/9P)も合わせてお求めください。

ラックマウントアダプタ

ターミナルユニット

警告灯ユニット

無償ダウンロード

試験結果収集ソフトウェア:Data Acquisition for TOS5300

Data Acquisition for TOS5300は、当社耐電圧試験器TOS5300シリーズの試験結果を収集し、管理するためのフリーソフトウェアです。Data Acquisition for TOS5300を使うことでデータの保存・検索・印刷が手軽に行え、さらには試験の実行・停止をPCから簡単に行えます。

Data Acquisition for TOS5300

検索画面

Catalog

Icon
Electrical Safety Testers
Icon
Hipot (Withstanding Voltage) & Insulation Resistance Tester|TOS5300 Series

Manual

Icon
TOS5300
GO TO GLOBAL SITE

2D CAD

Icon
TOS5300
GO TO GLOBAL SITE

Updater/Driver

Icon
TOS5300 – Application (Data Acquisition for TOS5300)
GO TO GLOBAL SITE
Icon
TOS5300 Series – IVI-COM Multi-Environment Drivers
GO TO GLOBAL SITE