PLZ-5W/5WZ_Ratings

ModelPLZ205WPLZ405WPLZ1205W
Operating voltage0.25 V to 150 V *1
Current *240 A80 A240 A *3
Power200W400W1200W
The minimum operating voltageapproximately 0.05 V. (At the load input terminals on the rear panel.)
Input resistance when the load is offApprox. 660 kΩ *4
Load input terminal’s isolation voltage±500 V

*1 In switching mode, for every slew rate setting of 1 A/μs, the minimum operating voltage (including the voltage drop due to the wiring inductance component) increases by approx. 150 mV for the PLZ205W, approx. 125 mV for the PLZ405W, and approx. 75 mV for the PLZ1205W. *2 If the input voltage is 1 V or less, the current is reduced by 10% per 0.1 V. *3 80 A for the load input terminals on the front panel. The specifications of the PLZ-5W are for the load input terminals on the rear panel and the load input terminals on the front panel may not meet the specifications. *4 In the case of parallel operation using the same models, approx. 660/number of units kΩ.