- Operation voltage: 0.25 V to 150 V
- High speed slew rate: 60 A/μs
- Arbitrary I-V characteristics: Installed “ARB mode”
- Parallel operation feature: The total current and power capacities can be increased to the maximum of 10.8 kW (2160 A) by connecting the booster units.
- New high visibility color display.
- Improved sequence feature (Maximum 10000 steps)
- LAN (LXI Compliant)/USB/RS232C standard interface *GPIB optional
- Setup memory can be saved to or loaded from a USB flash drive.
Line-up
Image | SKU | Rated operating voltage [V] | Rating current [A] | Rating Power [W] | 標準価格 | WEBかんたんお見積り |
---|---|---|---|---|---|---|
PLZ205W | 0.25 to 150 | 40 | 200 | 263,000円 (税込:289,300円) | ||
PLZ405W | 0.25 to 150 | 80 | 400 | 347,000円 (税込:381,700円) | ||
PLZ1205W | 0.25 to 150 | 240 | 1200 | 599,000円 (税込:658,900円) |
Specifications
Rating
Model | PLZ205W | PLZ405W | PLZ1205W |
---|---|---|---|
Operating voltage | 0.25 V to 150 V *1 | ||
Current *2 | 40 A | 80 A | 240 A *3 |
Power | 200W | 400W | 1200W |
The minimum operating voltage | approximately 0.05 V. (At the load input terminals on the rear panel.) | ||
Input resistance when the load is off | Approx. 660 kΩ *4 | ||
Load input terminal’s isolation voltage | ±500 V |
*1 In switching mode, for every slew rate setting of 1 A/μs, the minimum operating voltage (including the voltage drop due to the wiring inductance component) increases by approx. 150 mV for the PLZ205W, approx. 125 mV for the PLZ405W, and approx. 75 mV for the PLZ1205W. *2 If the input voltage is 1 V or less, the current is reduced by 10% per 0.1 V. *3 80 A for the load input terminals on the front panel. The specifications of the PLZ-5W are for the load input terminals on the rear panel and the load input terminals on the front panel may not meet the specifications. *4 In the case of parallel operation using the same models, approx. 660/number of units kΩ.
Constant current (CC) mode
Model | PLZ205W | PLZ405W | PLZ1205W | ||
---|---|---|---|---|---|
Operating range | Range H | 0 A to 40 A | 0 A to 80 A | 0 A to 240 A | |
Range M | 0 A to 4 A | 0 A to 8 A | 0 A to 24 A | ||
Range L | 0 A to 0.4 A | 0 A to 0.8 A | 0 A to 2.4 A | ||
Setting range | Range H | 0 A to 42 A | 0 A to 84 A | 0 A to 252 A | |
Range M | 0 A to 4.2 A | 0 A to 8.4 A | 0 A to 25.2 A | ||
Range L | 0 A to 0.42 A | 0 A to 0.84 A | 0 A to 2.52 A | ||
Resolution | Range H | 1 mA | 2 mA | 5 mA | |
Range M | 0.1 mA | 0.2 mA | 0.5 mA | ||
Range L | 0.01 mA | 0.02 mA | 0.05 mA | ||
Setting accuracy | Range H | ±(0.2% of set + 0.1% of range) | |||
Range M | ±(0.2% of set + 0.3% of range) | ||||
Range L | ±(0.2% of set + 1% of range) | ||||
Parallel operation | Range H | ±(0.4% of set + 0.8% of range) | |||
Range M | ±(0.4% of set + 0.8% of range) | ||||
Range L | ±(0.4% of set + 5% of range) | ||||
Input line regulation *1 | 4 mA | 8 mA | 24 mA | ||
Ripple | rms *2 | 4 mA | 8 mA | 24 mA | |
p-p *3 | 40 mA | 80 mA | 200 mA |
*1 When the input voltage is changed from 1 V to 150 V at a current of rated power / 150 V. *2 Measurement frequency bandwidth: 10 Hz to 1 MHz *3 Measurement frequency bandwidth: 10 Hz to 20 MHz
Constant resistance (CR) mode
Model | PLZ205W | PLZ405W | PLZ1205W | ||
---|---|---|---|---|---|
Operating range *1 | Range H | 40 S to 0.002 S (0.025 Ω to 500 Ω) | 80 S to 0.004 S (0.0125 Ω to 250 Ω) | 240 S to 0.012 S (0.0042 Ω to 83.333 Ω) | |
Range M | 4 S to 0.0002 S (0.25 Ω to 5000 Ω) | 8 S to 0.0004 S (0.125 Ω to 2500 Ω) | 24 S to 0.0012 S (0.042 Ω to 833.33 Ω) | ||
Range L | 400 mS to 0.02 mS (2.5 Ω to 50000 Ω) | 800 mS to 0.04 mS (1.25 Ω to 25000 Ω) | 2400 mS to 0.12 mS (0.42 Ω to 8333.3 Ω) | ||
Setting range | Range H | 42 S to 0 S (0.0238 Ω to Open) | 84 S to 0 S (0.0119 Ω to Open) | 252 S to 0 S (0.00397 Ω to Open) | |
Range M | 4.2 S to 0 S (0.238 Ω to Open) | 8.4 S to 0 S (0.119 Ω to Open) | 25.2 S to 0 S (0.0397 Ω to Open) | ||
Range L | 420 mS to 0 S (2.38 Ω to Open) | 840 mS to 0 S (1.19 Ω to Open) | 2520 mS to 0 S (0.397 Ω to Open) | ||
Resolution | Range H | 1 mS | 2 mS | 5 mS | |
Range M | 0.1 mS | 0.2 mS | 0.5 mS | ||
Range L | 0.01 mS | 0.02 mS | 0.05 mS | ||
Setting accuracy *2 | Range H | ±(0.5% of set + 0.5% of range) | |||
Range M | ±(0.5% of set + 0.5% of range) | ||||
Range L | ±(0.5% of set + 1.5% of range) | ||||
Parallel operation | Range H | ±(0.5% of set + 1.5% of range) | |||
Range M | ±(0.5% of set + 1.5% of range) | ||||
Range L | ±(0.5% of set + 5% of range) |
*1 Conductance [S] = input current [A]/input voltage [V] = 1 / resistance [Ω] *2 Converted value at the input current. At the sensing terminals during remote sensing.
Constant voltage (CV) mode
Model | PLZ205W | PLZ405W | PLZ1205W | |
---|---|---|---|---|
Operating range | Range H | 0.25 V to 150 V | ||
Range L | 0.25 V to 15 V | |||
Setting range | Range H | 0 V to 157.5 V | ||
Range L | 0 V to 15.75 V | |||
Resolution | Range H | 5 mV | ||
Range L | 0.5 mV | |||
Setting accuracy *1 | ±(0.1% of set + 0.1% of range) | |||
Parallel operation | ±(0.2% of set + 0.2% of range) | |||
Input voltage variation*2 | 12 mV |
*1 With the input voltage within the operating range, and at the sensing terminals during remote sensing. *2 For a current change in the range of 10% to 100% of the rating at an input voltage of 5 V (during remote sensing).
Constant power (CP) mode
Model | PLZ205W | PLZ405W | PLZ1205W | ||
---|---|---|---|---|---|
Operating range | Range H | 20 W to 200 W | 40 W to 400 W | 120 W to 1200 W | |
Range M | 2 W to 20 W | 4 W to 40 W | 12 W to 120 W | ||
Range L | 0.2 W to 2 W | 0.4 W to 4 W | 1.2 W to 12 W | ||
Setting range | Range H | 0 W to 210 W | 0 W to 420 W | 0 W to 1260 W | |
Range M | 0 W to 21 W | 0 W to 42 W | 0 W to 126 W | ||
Range L | 0 W to 2.1 W | 0 W to 4.2 W | 0 W to 12.6 W | ||
Resolution | Range H | 0.005 W | 0.01 W | 0.05 W | |
Range M | 0.0005 W | 0.001 W | 0.005 W | ||
Range L | 0.00005 W | 0.0001 W | 0.0005 W | ||
Setting accuracy | Range H | ±(0.5% of range + 0.04A×Vin *1) | ±(0.5% of range + 0.08A×Vin *1) | ±(0.5% of range + 0.24A×Vin *1) | |
Range M | ±(0.5% of range + 0.008A×Vin *1) | ±(0.5% of range + 0.016A×Vin *1) | ±(0.5% of range + 0.048A×Vin *1) | ||
Range L | ±(1% of range + 0.004A×Vin *1) | ±(1% of range + 0.008A×Vin *1) | ±(1% of range + 0.024A×Vin *1) | ||
Parallel operation | Range H | ±(2% of range + 0.4% current range ×Vin *1) | |||
Range M | ±(2% of range + 0.4% current range ×Vin *1) | ||||
Range L | ±(2% of range + 2.5% current range ×Vin *1) |
*1 Vin: Rear panel load input terminal voltage or sensing terminal voltage.
Arbitrary I-V characteristics (ARB) mode
Model | PLZ205W | PLZ405W | PLZ1205W |
---|---|---|---|
Operating range | Three to 100 points of current values can be set for the input voltage. The space between two points is linearly interpolated. | ||
Response speed | Response for input voltage minimum 50 μs. |
Voltmeter
Model | PLZ205W | PLZ405W | PLZ1205W | |
---|---|---|---|---|
Display | Range H | 0.00 V to 150.00 V | ||
Range L | 0.000 V to 15.000 V | |||
Accuracy | ±(0.1% of reading + 0.1% of range) | |||
Parallel operation (TYP) | ±(0.1% of reading + 0.1% of range) |
Ammeter
Model | PLZ205W | PLZ405W | PLZ1205W | ||
---|---|---|---|---|---|
Display | Range H | 0.000 A to 40.000 A | 0.000 A to 80.000 A | 0.00 A to 240.00 A | |
Range M | 0.0000 A to 4.0000 A | 0.0000 A to 8.0000 A | 0.000 A to 24.000 A | ||
Range L | 0.00 mA to 400.00 mA | 0.00 mA to 800.00 mA | 0.0000 A to 2.4000 A | ||
Accuracy | H, M range | ±(0.2% of reading + 0.3% of range) | |||
Range L | ±(0.2% of reading + 1% of range) | ||||
Parallel operation (TYP) | H, M range | ±(0.4% of reading + 0.8% of range) | |||
Range L | ±(0.4% of reading + 5% of range) |
Wattmeter
Model | PLZ205W | PLZ405W | PLZ1205W |
---|---|---|---|
Display | Displays the product of the voltmeter reading and ammeter reading. |
Switching mode
Model | PLZ205W | PLZ405W | PLZ1205W | |
---|---|---|---|---|
Operation mode | CC and CR | |||
Frequency setting range | 1.0 Hz to 100.0 kHz | |||
Frequency setting resolution | 1 Hz to 10 Hz | 0.1Hz | ||
11 Hz to 100 Hz | 1Hz | |||
110 Hz to 1000 Hz | 10Hz | |||
1.1 kHz to 10.0 kHz | 0.1kHz | |||
10 kHz to 100 kHz | 20 kHz, 50 kHz, 100 kHz | |||
Frequency setting accuracy | ±(0.5% of set) | |||
Duty cycle setting range, step *1 | 1 Hz to 10 Hz | 5.0% to 95.0%, 0.1% steps | ||
11 Hz to 100 Hz | ||||
110 Hz to 1000 Hz | ||||
1.1 kHz to 10.0 kHz | 5% to 95%, 1% steps | |||
10 kHz to 100 kHz | 10% to 90%, 10% steps |
*1 The minimum time span is 5 us. The minimum duty cycle is limited by the minimum time span.
Slew rate
Model | PLZ205W | PLZ405W | PLZ1205W | |
---|---|---|---|---|
Operation mode | CC | |||
Setting range | Range H | 0.01 A/ μs to 10 A/ μs | 0.02 A/ μs to 20 A/ μs | 0.06 A/ μs to 60 A/ μs |
Range M | 0.001 A/ μs to 1 A/ μs | 0.002 A/ μs to 2 A/ μs | 0.006 A/ μs to 6 A/ μs | |
Range L | 0.1 mA/ μs to 100 mA/ μs | 0.2 mA/ μs to 200 mA/ μs | 0.6 mA/ μs to 600 mA/ μs | |
Resolution | Range H | 0.01A/μs | 0.02A/μs | 0.06A/μs |
Range M | 0.001A/μs | 0.002A/μs | 0.006A/μs | |
Range L | 0.1mA/μs | 0.2mA/μs | 0.6mA/μs | |
Setting accuracy *1 | H, M range | ±(10% of set + 1.25μs) | ||
Range L | ±(12% of set + 5μs) |
*1 Time to change from 10% to 90% when the current is changed from 0% to 100% of the rated current
Soft start
Model | PLZ205W | PLZ405W | PLZ1205W |
---|---|---|---|
Operation mode | CC | ||
Time setting range | 100 μs, 200 μs, 500 μs, 1 ms, 2 ms, 5 ms, 10 ms, 20 ms, or off | ||
Time accuracy | ±(30% of set +10μs) |
Remote sensing
Model | PLZ205W | PLZ405W | PLZ1205W |
---|---|---|---|
compensation voltage | Approx. 7 V (total potential difference between the input terminals and sensing terminals). |
Protection functions
Model | PLZ205W | PLZ405W | PLZ1205W | |
---|---|---|---|---|
Overcurrent protection (OCP) | Setting range | 0.0 A to 44.0 A | 0.0 A to 88.0 A | 0.0 A to 264.0 A |
Resolution | 10mA | 10mA | 10mA | |
Protective operation | Either load off or limitation can be selected. | |||
Overpower protection (OPP) | Setting range | 0 W to 220 W | 0 W to 440 W | 0 W to 1320 W |
Resolution | 0.1W | 0.1W | 0.1W | |
Protective operation | Either load off or limitation can be selected. | |||
Undervoltage protection (UVP) | Setting range | 0.00 V to 150.00 V, or off | ||
Resolution | 0.01V | |||
Protective operation | Load off | |||
Watchdog protection(WDP) | Setting range | 1 s to 3600 s or off | ||
Protective operation | Load off |
Sequence function
Model | PLZ205W | PLZ405W | PLZ1205W |
---|---|---|---|
Operation mode | CC, CR, CV, CP | ||
Maximum number of programs | 30 | ||
Maximum number of steps | 10000 | ||
Step execution time | 25 μs to 1000 h | ||
Time resolution | 25μs |
Others
Model | PLZ205W | PLZ405W | PLZ1205W | |
---|---|---|---|---|
Elapsed time display | Displays the time from load on to load off. | |||
Range | 1s to 999h 59min 59s. | |||
Integrated current display | Displays the integrated current from load on to load off. | |||
Integrated power display | Displays the integrated power from load on to load off. | |||
Auto load off timer | Automatically turns off the load after the specified time elapses. | |||
Setting range | 1s to 3599999s, or off. |
EXT CONT connector
Model | PLZ205W | PLZ405W | PLZ1205W | |
---|---|---|---|---|
Load on/off control input | Logic level switchable. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 3.5 V to 5 V, LOW: 0 V to 1.5 V. | |||
Range control input | The range can be switched between L, M, and H using a 2 bit signal. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 3.5 V to 5 V, LOW: 0 V to 1.5 V. | |||
Alarm input | An alarm is activated with a voltage between 0 V and 1.5 V. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 3.5 V to 5 V, LOW: 0 V to 1.5 V. | |||
Alarm clearing input | After an alarm occurs, eliminate the root cause of the alarm, and change the input to pin 5 of the EXT CONT connector from a low level signal to a high level signal. The alarm will be cleared on the rising edge of this signal. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 3.5 V to 5.0 V, LOW: 0 V to 1.5 V. | |||
Trigger input | Paused sequence operation resumes when a voltage between 0 V and 0.8 V is received. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 2 V to 5 V, LOW: 0 V to 0.8 V. | |||
External voltage control input (CC, CR, CP mode) | Controls the load settings of CC, CR, CP mode through external voltage input. The input impedance is approx. 10 kΩ. CC: The setting can be controlled in the range of 0% to 100% of the rated current through external voltage input of 0 V to 10 V. CR: The setting can be controlled in the range of 0% to 100% of the conductance setting through external voltage input of 0 V to 10 V. CP: The setting can be controlled in the range of 0% to 100% of the rated power through external voltage input of 0 V to 10 V. | |||
Setting accuracy | ± (1% of range) (TYP value of H range in CC mode) | |||
External voltage control input (CV mode) | The load setting of CV mode can be controlled through external voltage input. The rated voltage can be controlled in the range of 0% to 100% with 0 V to 10 V. The input impedance is approx. 10 kΩ. | |||
Setting accuracy | ± (1% of range) (TYP value) | |||
External voltage control input (superimposing in CC mode) | Controls the load setting of CC mode by adding current through external voltage input. Adds current in the range of -100% to 100% of the rated current for -10 V to 10 V. The input impedance is approx. 10 kΩ. | |||
Setting accuracy | ± (1% of range) (TYP value of H range) | |||
Load-on status output | On when load is on. Open-collector output from a photocoupler. *1 | |||
Range status output | Outputs current range state L, M, and H using 2 bits. Open-collector output from a photocoupler. *1 | |||
ALARM 1 output | Turns on when overvoltage detection, reverse-connection detection, overheat detection, alarm input detection, front-panel load input terminal overcurrent detection, or parallel operation anomaly detection is activated. Open-collector output from a photocoupler. *1 | |||
ALARM 2 output | Turns on when OCP, OPP, UVP, or WDP is activated. | |||
DIGITAL 0 / DIGITAL 1 output | Logic signal output during a step of a sequence. Output impedance: approx. 330 Ω, output voltage: approx. 3.3 VEMF | |||
DIGITAL 2 output | Input/output switchable. Output: Logic signal output during a step of a sequence. The output impedance is 330 Ω.Input: Trigger input signal for the sequence and the measurement functions. The thresholds are HIGH: 2 V to 5 V, LOW: 0 V to 0.8 V. | |||
Current monitor output | Outputs 0 V to 10 V for 0% to 100% of the rated current of each range. | |||
Accuracy | ± (1% of range) (TYP value of H range) | |||
Short signal output | Relay contact turns on when the short function is turned on (30 Vdc/1 A). |
*1 The maximum voltage that can be applied to the photocoupler is 30 V. The maximum current is 4 mA.
BNC connector
Model | PLZ205W | PLZ405W | PLZ1205W | |
---|---|---|---|---|
Trigger output | Transmits 10 μs pulses when trigger output is ON during sequence operation and during step execution. Transmits 1 μs pulses during switching operation. | |||
Current monitor output | Outputs 0 V to 2 V for 0% to 100% of the rated current of each range. | |||
Accuracy | ± (1% of range) (TYP value of H range) | |||
Isolation voltage | ±30V |
Communication function
Model | PLZ205W | PLZ405W | PLZ1205W |
---|---|---|---|
LAN | IEEE 802,3 100Base-TX / 10Base-T Ethernet IPv4, RJ-45 connector | ||
RS232C | D-SUB 9-pin connector Baud rate: 9600, 19200, 38400, 115200 bps Data length: 8 bits, Stop bits: 1 bit, Parity bit: None, Flow control: None, CTS-RTS | ||
USB | Complies with the USB 2.0 specification. Data rate: 480 Mbps (High speed) Complies with the USBT MC-USB488 device class specifications. |
General specifications
Model | PLZ205W | PLZ405W | PLZ1205W | |
---|---|---|---|---|
Input voltage range/ Input frequency range | 100 Vac to 240 Vac (90 Vac to 250 Vac) single phase, continuous / 47 Hz to 63 Hz | |||
Power consumption | 50VAmax | 50VAmax | 85VAmax | |
Inrush current (peak value) | 45A Peak | |||
Environmental conditions | Operating temperature range / Operating humidity range | 0 °C to 40 °C (32 °F to 104°F) / 20%rh to 85%rh (no condensation) | ||
Storage temperature range / Storage humidity range | -20 °C to 70 °C (-4 °F to 158°F) / 90%rh or less (no condensation) | |||
Installation location | Indoor use, altitude of up to 2000 m, overvoltage category II. | |||
Insulation resistance | Between primary and input terminals | 500Vdc, 30 MΩ or more (70%rh or less) | ||
Between primary and chassis | ||||
Between input terminals and chassis | ||||
Withstanding voltage | Between primary and input terminals | No abnormalities at 1500 Vac for 1 minute. | ||
Between primary and chassis | No abnormalities at 1500 Vac for 1 minute. | |||
Between input terminals and chassis | No abnormalities at 750 Vac for 1 minute. | |||
Dimensions Unit: mm (inches) | 214.5 (8.45)W×124 (4.88)H×400 (15.75)Dmm(inches) | 429.5 (16.91)W×128 (5.04)H×400 (15.75)Dmm(inches) | ||
Weight | Approx. 7 kg (15.4 lb.) | Approx. 7.5 kg (16.5 lb.) | Approx. 14 kg (30.9 lbs) | |
Accessories | Power cord, Rear-panel load input terminal cover, Load input terminal screw set (2 sets), Screws for the rear-panel load input terminal cover (2 pcs.), Front-panel load input terminal cover, Front-panel load input knob set, External control connector kit, Setup Guide, CD-ROM, Quick Reference, Safety Information | |||
Electromagnetic compatibility (EMC) *1 *2 | Complies with the requirements of the following directive and standards. EMC Directive 2014/30/EU, EN 61326-1 (Class A*3), EN 55011 (Class A*3, Group 1*4), EN 61000-3-2, EN 61000-3-3 Applicable under the following conditions.The maximum length of all cabling and wiring connected to the PLZ-5W must be less than 3 m. | |||
Safety *1 | Complies with the requirements of the following directive and standards. Low Voltage Directive 2014/35/EU *2 EN 61010-1 (Class I *5, Pollution Degree 2 *6) |
*1 Does not apply to specially ordered or modified PLZ-5Ws. *2 Limited to products that have the CE/UKCA mark on their panels. *3 This is a Class A equipment. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromag-netic emissions to prevent interference to the reception of radio and television broadcasts. *4 This is a Group 1 equipment. This product does not generate and/or use intentionally radio-frequency energy, in the form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose. *5 This is a Class I equipment. Be sure to ground this product’s protective conductor terminal. The safety of this product is only guaranteed when the product is properly grounded. *6 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary con-ductivity caused by condensation.
Options
GPIB Converter
Parallel-operation cable
Rack Adapter/Bracket Option
PLZ205W、PLZ405W
PLZ1205W