General Specifications

ItemDME1700DME1701
Nominal voltage range (allowable voltage range)100 Vac to 240 Vac (90 Vac to 264 Vac)
Power consumption25 VAmax
Environmental conditionsOperating temperature range / Operating humidity range0 °C to 50 °C (32 °F to 122 °F) / 80 %rh or less (no condensation)
Storage temperature range-40 °C to 70 °C (-40 °F to 158 °F)
AltitudeUp to 2000 m
Dimensions / Weight212.8(8.38)W × 88.3(3.48)H× 272.3(10.72)D mm(inches) (Main unit only. Protrusions and other parts are not included) / 2.5 kg (5.5 lbs)
Interface–USB, LAN
Safety*1Complies with the requirements of the following directive and standards.
Low Voltage Directive 2014/35/EU*4
EN 61010-1 (Class I *2, Pollution Degree 2 *3), EN 61010-2-030
Measurement Category II 300 V
EN 61010-031
Electromagnetic compatibility (EMC)*1 *4Complies with the requirements of the following directive and standards.
EMC Directive 2014/30/EU, EN 61326-1, EN 61326-2-1,
EMI: CISPR 11 (Class A *5, Group I *6),
EN 61000-3-2, EN 61000-3-3
EMS: EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5,
EN 61000-4-6, EN 61000-4-8, EN 61000-4-11
Applicable under the following conditions: The maximum length of all cabling and wiring connected to the product must be less than 3 m.
Input protectionUT HI terminal1000 Vpk
SENSE HI terminal350 Vpk (referenced to LO terminal)
SENSE LO terminal
Insulation resistance (Between each terminal and chassis)500 Vpk, >>10 GΩ
Capacity (Between each terminal and chassis)< 300 pF

*1 Does not apply to specially ordered or modified products.
*2 This is a Class I instrument. Be sure to ground this product’s protective conductor terminal. The safety of this product is guaranteed only when the product is properly grounded.
*3 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary conductivity caused by condensation.
*4 Only for models with CE marking / UKCA marking on their body.
*5 This is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts.
*6 This product belongs to Group 1 products. This product does not generate and/or use intentionally radio-frequency energy, in the form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose.