| Terminal No. | Signal name | Function | |
|---|---|---|---|
| 1 | LOC/REM SELECT | Local/remote switching | |
| 2 | P | Current balance terminal for master-slave parallel operation | |
| 3 | I_MON | Output current monitoring terminal | |
| 4 | LOC/REM MON | Local/remote status output | |
| 5 | IPGM | Output current control using external voltage or external resistance | |
| 6 | VPGM | Output voltage control using external voltage or external resistance | |
| 7 | COM | Common ground for VMON, IMON, CV/CC, and LOC/REM signals (connected internally to the negative sensing terminal (-S)) | |
| 8 | CV/CC | Constant voltage/constant current operation mode indication terminal (The ground is COM.) | |
| 9 | COM | Common ground for VMON, IMON, CV/CC, and LOC/REM signals (connected internally to the negative sensing terminal (-S)) | |
| 10 | V_MON | Output voltage monitoring terminal | |
| 11 | IPGM_RTN | Ground for IPGM | |
| 12 | VPGM_RTN | Ground for VPGM (connected internally to the negative sensing terminal (-S)) | |