PLZ-5WH2_External Control

Terminal No.In/Out *1Signal nameDescription
1–STATUS COMStatus signal common for pins 14 to 16.
2NC––
3NC––
4NC––
5INALARM CLEARAlarm clearing input
6INALARM INAlarm input
7NC––
8NC––
9INTRIG INPUTTrigger input. Resumes program execution if Wait(post) was set to Trig IN in a sequence step and the program was paused.
10–A COMThis is connected to the chassis.
11OUTDIGITAL 0DIGITAL0 output. Sequence control possible.
12OUTDIGITAL 1DIGITAL1 output. Sequence control possible.
13IN/OUTDIGITAL 2DIGITAL2 I/O. Input/output switchable. Sequence signal output or the trigger input of sequences and measurement function.
14OUTALARM1ALARM1 output. ON when overvoltage detection, reverse-connection detection, overheat detection, alarm input detection, or parallel operation anomaly detection is activated, and also during external alarm input.
15OUTALARM2ALARM2 output. ON during OCP, OPP, UVP, or WDP operation.
16OUTLOAD ON STATUSLoad-on status output. ON during load on.
17NC––
18INLOAD ON / OFF CONTLoad on/off control input. Logic level switchable.
19–A COMThis is connected to the chassis.
20INEXT CONT ADDExternal voltage control input. Controls the load setting of CC mode by adding current.
21INEXT CONT MODEExternal voltage control input. Controls the load values of CC, CR, and CP modes.
22INEXT CONT CVExternal voltage control input. Controls the voltage of CV mode.
23–A COMThis is connected to the chassis.
24OUTIMONCurrent monitor output.
25NC––

*1 1000 V reinforced insulation between each terminal and the DC INPUT terminal.