27805

PLZ-U_Frame Details

ModelPLZ-30FPLZ-50F
Rated supply voltage100 VAC to 240 VAC (90 VAC to 250 V) single phase
Rated frequency50 Hz or 60 Hz (47 Hz to 63 Hz)
Power consumptionFrame alone33 VA or less40 VA or less
When load units are installed in all channels300 VAmax500 VAmax
Cooling methodForced air cooling using a heat sensing variable speed fan.
Operating temperature range0 °C to 40 °C (32 °F to 104 °F)
Operating humidity range20 % to 85 % RH (without condensation)
Storage temperature range–20 °C to 70 °C (-4 °F to 158 °F)
Storage humidity range90 % RH or less (without condensation)
Insulation resistanceBetween primary and chassis500 VDC, 30 MΩ or more (ambient humidity of 70% RH or less)
Withstanding voltageBetween primary and chassisNo abnormalities at 1500 VAC for 1 minute.
Earth continuity25 Aac, 0.1 Ω or less
Battery backupBacks up the setup data immediately before the power is turned off Battery life: 3 years or longer (at 25 °C)
Number of installable load modules35
Dimensions (mm)See outline drawing.
WeightFrame aloneApprox. 5 kg (11.02 lb)Approx. 7 kg (15.43 lb)
AccessoriesPower cord1 pc. (with SVT3, 18AWG, 3-prong plug, cable length of 2.4 m)
Blank panel (front panel)2 pcs. maximum*14 pcs. maximum*1
Protection dummy plug2 pcs. (for the FRAME CONT connector, attached to the unit)
Operation Manuals1 pc.
Electromagnetic compatibility*2*3Complies with the requirements of the following directive and standard.
EMC Directive 2014/30/EU
EN 61326-1 (Class A)
EN55011 (Class A*4, Group 1*5)
EN 61000-3-2
EN 61000-3-3
SafetyComplies with the requirements of the following directive and standard.
Low Voltage Directive 2014/35/EU*3
EN 61010-1 (Class I*6, Pollution degree 2*7)

*1 In products that have load units installed, blank panels are installed in the empty slots. In products that contain the frame alone, the maximum number of blank panels are installed. *2 Does not apply to specially ordered or modified PLZ-U *3 Limited to products that have the CE mark/UKCA mark on their panels. *4 This is a Class A equipment. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts. *5 This is a Group 1 equipment. This product does not generate and/or use intentionally radio-frequency energy, in the from of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose. *6 This is a Class I equipment. Be sure to ground the this product’s protective conductor terminal. The safety of this product is only guaranteed when the product is properly grounded. *7 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary conductivity caused by condensation.


Related specifications : PLZ-U Series