Inter-frame control | Controls up to four slave frames from the master frame. | |
---|---|---|
Enables you to turn on/off the load, recall presets ABC on all channels simultaneously, and recall setup memories 0 to 3. | ||
External control | Recall input of preset mem-ories A, B, and C | Recalls preset memories A, B, and C on all channels simultaneously |
Setup memory recall input | Recalls the setup memory 0 to 3 | |
Enable input | Enables the turning on/off of the load, recalling of presets ABC on all channels simultaneously, and recalling of setup memories 0 to 3. | |
Load-on input | Turns on the load on all channels simultaneously. | |
Load on status output | On when the load is on (open collector output) | |
Alarm status output | On when the alarm is on (open collector output) | |
Internal power output | 5 V and maximum output current of 100 mA | |
Input signal | Low active, pull up to 5 V using 10 kΩ. Low level input voltage: 0 V to 1 V, high level input voltage: 4 V to 5 V | |
Output signal | Open drain, output withstand voltage of 30 VDC, output satura-tion voltage of approximately 0.7 V, and maximum output current of 100 mA. |
27805
PLZ-U_Inter-frame control and external control
Related specifications : PLZ-U Series
- PLZ-U_Diverse load on/off operations
- PLZ-U_Load Unit
- PLZ-U_Frame section (for page)
- PLZ-U_Switching function
- PLZ-U_Sequence setting parameters
- PLZ-U_Parallel operation
- PLZ-U_Channel-synchronized operations
- PLZ-U_High precision and high resolution
- PLZ-U_Variable slew rate
- PLZ-U_Frame Details
- PLZ-U_CR mode
- PLZ-U_General specifications
- PLZ-U_Communication function
- PLZ-U_External analog control
- PLZ-U_Inter-frame control and external control
- PLZ-U_Remote sensing & Other
- PLZ-U_Protection function
- PLZ-U_Sequence function
- PLZ-U_Soft start
- PLZ-U_Slew rate
- PLZ-U_Switching mode
- PLZ-U_Wattmeter
- PLZ-U_Ammeter
- PLZ-U_Voltmeter
- PLZ-U_CV mode
- PLZ-U_CC mode
- PLZ-U_Rating
- PLZ-U_Frame
- PLZ-U_Load Unit