PMX-Multi_Protection Function

ModelPMX32-3DUPMX32-3TRPMX32-2QU
Overvoltage protection (OVP)OperationTurns the output off, displays “OVP,” and displays “ALARM” (red).
Selectable range10% to 110% of the rated output voltage
Setting accuracy±(1 % of rating)
Setting resolution1 mV
Overcurrent protection (OCP)Action *1Turns the output off, displays “OCP,” and displays “ALARM” (red).
Selectable range10% to 110% of the rated output current
Setting accuracy±(1 % of rating)
Setting resolution0.1 mA
Overheat protection (OHP)OperationTurns the output off, displays “OHP,” and displays “ALARM” (red).

*1. This does not protect against the discharge current peak that is generated from the capacitors inside the product’s output section when the load is changed suddenly.