Voltage/thermometer unit

OP02-PFX

OP02-PFX

110,000 (税込:121,000

  • Voltage/thermometer unit
  • PFX2512 / 2532
カート機能が動くまでの
SKU: OP02-PFX

Overview

Features

Voltage/thermometer unit

When monitoring the status of each cell of the battery pack is required, install the optional voltage/ thermometer unit OP02-PFX. By installing OP02- PFX on PFX2512/2532, voltages/temperatures for four cells are able to be monitored/logged with one sheet, respectively. (Up to 3 boards can be installed.) For a battery pack connected in series, monitoring of balance among cells is important. With OP02-PFX, the charge and discharge control can be stopped according to the status of each cell.In addition, it is equipped with a function to stop charge and discharge when the balance beteen the cells in the battery pack becomes large (maximum voltage – minimum voltage). Furthermore, at the time of pulse discharge, voltage can be measured at the same time as the synchronization of all cells for load fluctuations.


Voltage/thermometer unit [OP02-PFX]

Expanded features

  • Monitor data: Cell voltage, cell temperature.
  • Charge stop conditions: Cell voltage, cell temperature and potential difference among cells
  • Discharge stop conditions: Cell voltage and potential difference among cells, cell temperature
  • Charge/discharge conditions: Cell voltage, cell temperature, Cell unbalance
  • Protective functions: Cell voltage, cell temperature and potential difference among cells

Restricted functions

  • The maximum number of channels that 1 unit of personal computer can control is 5 ch.

Specifications

Cell measurement function

Open in a new windowZOOM

Static

OP02-PFX
Cell voltageAverage voltage of the every 100 ms
Cell temperatureTemperature measurement function to make thermocouple as temperature detecting element, updated every second
Cell voltage measurement

Open in a new windowZOOM

Static

OP02-PFX
Number of measured terminals4
Measurable range *1-2.0000 V to 20.0000 V
Accuracy *2±(0.05 % of reading + 0.02 % of rating)
Resolution0.1mV
Measured valueAverage voltage of the every 100 ms
Measurement interval100ms
Cell temperature measurement

Open in a new windowZOOM

Cell temperature measurement *3

OP02-PFX
Number of measured terminals4
Thermocouple typeK type
Measurable range *4-100.0 °C to 400.0 °C
Accuracy *2 *5± 1.5 °C (TYP values)
Reference junction accuracy *2 *6± 0.5 °C (TYP values)
Resolution0.1℃
Measurement interval1 s

*1 You can apply a voltage from -20 V to 22 V. *2 Ambient temperature at 18 °C to 28 °C. *3 The temperature scale conforms to JIS C 1602-1995 (ITS-90). (ITS-90 is an international temperature scale.) *4 Depending on your thermocouple’s specifications (thermocouple class, wire diameter and insulation), the usable temperature range will vary. *5 When the voltage that the thermocouple calibrator produces is measured. *6 This shows the internal sensor performance. This indicates the temperature measurement accuracy of the thermocouple connector. Thermometer accuracy = Measurement accuracy + reference junction compensation + thermocouple tolerance

Manual