0

General specifications

PFX2512PFX2532
Nominal input rating100 Vac to 240 Vac, 50 Hz/60 Hz
Input voltage range90 Vac to 250 Vac
Power consumption60 VAmax (when three OP02-PFXs are installed: 80 VAmax)
Operating temperature and humidity range0 °C to 40 °C (32 °F to 104 °F), 20 %rh to 85 %rh (no condensation)
Storage temperature and humidity range-10 °C to 60 °C (14 °F to 140 °F), 0 %rh to 90 %rh (no condensation)
Operating environmentIndoors, overvoltage category II
AltitudeUp to 2000 m
Isolation voltageBetween I/O terminals and chassis± 60 Vmax± 60 Vmax
Insulation resistance *4Between primary and chassis500 Vdc, 30 MΩ or greater, 70 %rh humidity or less
Primary and across the I/O terminals
Withstanding voltageBetween primary and chassisNo abnormalities at 1500 Vac for 1 minute
Primary and across the I/O terminals
Safety *1Complies with the require- ments of the following directive and standard. Low Voltage Directive 2014/35/EU *2 EN61010-1 (Class I *3, Pol- lution degree 2 *4)
Electromagnetic compatibility *1 *2Complies with the require- ments of the following directive and standard. EMC Directive 2014/30/EU EN61326-1 (Class A *5) EN55011 (Class A *5, Group 1 *6) EN61000-3-2, EN61000-3-3
Applicable under the following conditions. The maximum length of all cabling and wiring connected to the PFX2512 is less than 5 m.Applicable under the following conditions. The maximum length of all cabling and wiring connected to the PFX2532 is less than 3 m.
DimensionsSee the outline drawing
WeightApprox. 7 kg (15.43 lb)Approx. 17 kg (37.48 Ib)
AccessoriesPower cord *71 pc1 pc
Cable with Solderless terminal4 pcs (Red: 2 pcs, White: 2 pcs) 45 cm each (17.72 inch)
I/O terminal cover setThree terminal covers, six cable ties for locking
I/O terminal M8 screw set6 sets
Load input terminal cover setCover, four auxiliary bands
26-core flat cable1 pc1 pc
20-core flat cable1 pc1 pc
26-core cable (with ferrite core)1 pc
Sensing connector1 pc1 pc
Sensing connector cover setOne cover set, one cable tie for locking
Thermistor1 pc1 pc
Lock lever2 pcs2 pcs
LAN cable1 pc. Straight type1 pc. Straight type
Operation Manuals1 copy1 copy

*1 DoesnotapplytospeciallyorderedormodifiedPFX2512sandPFX2532s. *2 Limited to products that have the CE/UKCA mark on their panels. When the optional OP03-PFX Voltmeter Unit is used, compliance is achieve by using the optional TL12-PFX sensing cable (length: approx. 3 m, connector area: with cover, with core). *3 ThisisaClassIequipment.BesuretogroundthePFX2512’sandPFX2532’sprotectiveconduc- tor terminal. The safety of this product is only guaranteed when the product is properly grounded. *4 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive pol- lution will occur except for an occasional temporary conductivity caused by condensation. *5 This is a Class A equipment. The PFX2512 and PFX2532 is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts. *6 This is a Group 1 equipment. The PFX2512 and PFX2532 does not generate and/or use intention- ally radio-frequency energy, in the from of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose. *7 Because the power cord does not comply with CE/UKCA, it may not be included depending on the shipment destination.


Related specifications : PFX2500 Series

Please feel free to contact us with any questions or concerns.

Download a Product CatalogView List