Static
Charge / discharge current measurement
| PFX2512 | PFX2532 |
---|
Range | 0.0000 A to 50.0000 A
*1 | 0.000 A to 200.000 A
*1 |
---|
Accuracy
*2 | ± (0.15 % of reading + 0.02 % of rating) | ± (0.2 % of reading + 0.1 % of rating) |
---|
Resolution | 0.1 mA | 1 mA |
---|
Voltage measurement
| PFX2512 | PFX2532 |
---|
Range | 60 V range | -6.0000 V to 60.0000 V
*3 |
---|
6 V range | -6.0000 V to 60.0000 V
*4 |
---|
Accuracy
*2 *5 | 60 V range | ± (0.05 % of reading + 0.02 % of rating) |
---|
6 V range | ± (0.05 % of reading + 0.04 % of rating) |
---|
Resolution
*5 | 0.1 mV |
---|
Power measurement
| PFX2512 | PFX2532 |
---|
Range | 0.000 W to 3000.000 W | 0.0 W to 12000.0 W |
---|
Accuracy | Software calculation (voltage measurement ✕ current measurenent) | |
---|
Resolution | 1 mW | 100 mW |
---|
Current capacity calculation
| PFX2512 | PFX2532 |
---|
Range | 0.000 Ah to 2000.000 Ah |
---|
Accuracy
*2 | Depends on the current measurement accuracy and the time accuracy |
---|
Resolution | 1 mAh |
---|
Power capacity calculation
| PFX2512 | PFX2532 |
---|
Range | 0.000 Wh to 120000.000 Wh |
---|
Accuracy
*2 | Depends on the voltage measurement accuracy, current measurement accuracy and the time accuracy |
---|
Resolution | 1 mWh |
---|
Time
*6
| PFX2512 | PFX2532 |
---|
Accuracy
*2 *7 | ±10 ppm (TYP values) |
---|
Pattern
Charge / discharge current measurement
| PFX2512 | PFX2532 |
---|
Range | -50.0000 A to 50.0000 A
*1 | -200.000 A to 200.000 A
*1 |
---|
Accuracy
*2 | ± (0.2 % of reading + 0.03 % of rating) | ± (0.2 % of reading + 0.1 % of rating) |
---|
Resolution | 0.1 mA | 1 mA |
---|
Measured value | Average current, Update a data per period of 1 s |
---|
Voltage measurement
| PFX2512 | PFX2532 |
---|
Range | 60 V range | -6.0000 V to 60.0000 V *3 |
---|
| 6 V range | -1.0000 V to 6.0000 V *4 |
---|
Accuracy
*2 | 60 V range | ± (0.05 % of reading + 0.02 % of rating) |
---|
| 6 V range | ± (0.05 % of reading + 0.04 % of rating) |
---|
Resolution
*5 | 0.1 mV |
---|
Power measurement
| PFX2512 | PFX2532 |
---|
Range | -3000.000 W to 3000.000 W | -12000.00 W to 12000.00 W |
---|
Accuracy
*2 | Software calculation (voltage measurement ✕ current measurenent) |
---|
Resolution | 1 mW | 10 mW |
---|
Current capacity calculation
| PFX2512 | PFX2532 |
---|
Range | -2000.000 Ah to 2000.000 Ah |
---|
Accuracy
*2 | Depends on the current measurement accuracy and the time accuracy |
---|
Resolution | 1mAh |
---|
Power capacity calculation
| PFX2512 | PFX2532 |
---|
Range | -120000.000 Wh to 120000.000 Wh |
---|
Accuracy
*2 | Depends on the voltage measurement accuracy, current measurement accuracy and the time accuracy |
---|
Resolution | 1 mWh |
---|
Time
*6
| PFX2512 | PFX2532 |
---|
Accuracy
*2 *7 | ±10 ppm (TYP values) |
---|
*1 Measurable range: -210.000 A to 210.000 A (TYP). However, the accuracy is not guaranteed for values outside of the range listed in the table. *2 Ambient temperature at 18 °C to 28 °C. *3 Measurable range: -6.500 V to 65.000 V (TYP). However, the accuracy is not guaranteed for values outside of the range listed in the table. *4 Measurable range: -6.500 V to 6.500 V (TYP). However, the accuracy is not guaranteed for values outside of the range listed in the table. *5 The same for the 6 V range and 60 V range. *6 Accuracy of the elapsed time (Cutoff condition) when charging / discharging or resting. *7 Monthly error: approximately 30 seconds.
High speed sampling
Current measurement
| PFX2512 | PFX2532 |
---|
Range
*1 | -50.0000 A to 50.0000 A | -200.000 A to 200.000 A |
---|
Accuracy
*1 *2 *3 | 1 ms sampling | ± (0.2 % of reading + 0.5 % of rating) | ± (0.4 % of reading + 0.5 % of rating) |
---|
10 ms sampling | ± (0.15 % of reading + 0.05 % of rating) | ± (0.3 % of reading + 0.1 % of rating) |
---|
100 ms sampling | ± (0.15 % of reading + 0.02 % of rating) | ± (0.2 % of reading + 0.1 % of rating) |
---|
Resolution | 1 ms sampling | 0.1 mA | 1 mA |
---|
10 ms sampling |
---|
100 ms sampling |
---|
Voltage measurement
| PFX2512 | PFX2532 |
---|
Range
*1 | 60 V range | -6.0000 V to 60.0000 V
*4 |
---|
6 V range | -6.0000 V to 60.0000 V
*5 |
---|
Accuracy
*1 *2 *3 | 1 ms sampling *6 | ± (0.1 % of reading + 0.1 % of rating) |
---|
10 ms sampling *6 | ± (0.1 % of reading + 0.05 % of rating) |
---|
100 ms sampling | 60 V range: ± (0.05 % of reading + 0.02 % of rating) |
---|
6 V range: ± (0.05 % of reading + 0.04 % of rating) |
Resolution | 1 ms sampling | 0.1 mV. The same for all sampling settings. |
---|
10 ms sampling |
---|
100 ms sampling |
---|
*1 The accuracy is not guaranteed for values outside of the rated output range. *2 Ambient temperature at 18 °C to 28 °C. *3 The wavering caused by the ripple noise and AC line noise (50 Hz/ 60 Hz) of the DC power supply that you are using is not included. *4 Measurable range: -6.500 V to 65.000 V (TYP). However, the accuracy is not guaranteed for values outside of the range listed in the table. *5 Measurable range: -6.500 V to 6.500 V (TYP). However, the accuracy is not guaranteed for values outside of the range listed in the table. *6 The same for the 6 V range and 60 V range.