PBZ_BP_Input / Output
This table is part of the specifications for:PBZ BP Series
| Item/Model | PBZ20-120 BP | PBZ20-140 BP | PBZ20-160 BP | PBZ20-180 BP | PBZ20-200 BP |
|---|
| Input rating | Nominal input voltage | 200 Vac to 240 Vac, single phase | 200 Vac, single phase |
|---|
| Voltage range | 180 Vac to 250 Vac | 180 Vac to 220 Vac |
|---|
| Frequency range | 47 Hz to 63 Hz |
|---|
| Current | 30 Aac or less | 35 Aac or less | 40 Aac or less | 45 Aac or less | 50 Aac or less |
|---|
| Inrush current | 240 Apeak or less | 280 Apeak or less | 320 Apeak or less | 360 Apeak or less | 400 Apeak or less |
|---|
| Power | 5400 VA or less | 6300 VA or less | 7200 VA or less | 8100 VA or less | 9000 VA or less |
|---|
| Power factor | 0.95 TYP (when the input voltage is 200 V) |
|---|
| Output rating | Power | 2400 W | 2800 W | 3200 W | 3600 W | 4000 W |
|---|
| Voltage | ±20 V |
|---|
| Current | ±120 A | ±140 A | ±160 A | ±180 A | ±200 A |
|---|
| Output terminal | Output terminal | Rear-panel output terminals (OUTPUT1, OUTPUT2) |
|---|
| Isolation voltage | 300 Vdc Only the output’s COM terminal can be grounded. |
|---|
| Item/Model | PBZ40-60 BP | PBZ40-70 BP | PBZ40-80 BP | PBZ40-90 BP | PBZ40-100 BP |
|---|
| Input rating | Nominal input voltage | 200 Vac to 240 Vac, single phase | 200 Vac, single phase |
|---|
| Voltage range | 180 Vac to 250 Vac | 180 Vac to 220 Vac |
|---|
| Frequency range | 47 Hz to 63 Hz |
|---|
| Current | 30 Aac or less | 35 Aac or less | 40 Aac or less | 45 Aac or less | 50 Aac or less |
|---|
| Inrush current | 240 Apeak or less | 280 Apeak or less | 320 Apeak or less | 360 Apeak or less | 400 Apeak or less |
|---|
| Power | 5400 VA or less | 6300 VA or less | 7200 VA or less | 8100 VA or less | 9000 VA or less |
|---|
| Power factor | 0.95 TYP (when the input voltage is 200 V) |
|---|
| Output rating | Power | 2400 W | 2800 W | 3200 W | 3600 W | 4000 W |
|---|
| Voltage | ±40 V |
|---|
| Current | ±60 A | ±70 A | ±80 A | ±90 A | ±100 A |
|---|
| Output terminal | Output terminal | Rear-panel output terminals (OUTPUT1, OUTPUT2) |
|---|
| Isolation voltage | 300 Vdc Only the output’s COM terminal can be grounded. |
|---|