Static
Constant current charge/discharge
| PFX2512 | PFX2532 |
---|
Range *1 | 0.000 A to 50.000 A | 0.000 A to 200.000 A |
---|
Accuracy *2 | *3 |
---|
Resolution | 1 mA |
---|
Constant voltage charge/discharge
| PFX2512 | PFX2532 |
---|
Range *1 | 60 V range | 0.000 V to 60.000 V |
---|
6 V range | 0.000 V to 6.000 V |
---|
Accuracy *2 | *3 |
---|
Resolution | 1 mV |
---|
Constant cell voltage charge/ discharge *4
| PFX2512 | PFX2532 |
---|
Range *1 | 0.000 A to 20.000 V |
---|
Accuracy *2 | *3 |
---|
Resolution | 1 mV |
---|
Constant power discharge
| PFX2512 | PFX2532 |
---|
Range *1 | 0.1 W to 3000.0 W | 1 W to 12000 W |
---|
Accuracy *2 | ±(0.5 % of set + 1 W) *5 | ±(0.5 % of set + 10 W) *5 |
---|
Resolution | 10 mW | 1 W |
---|
Pattern *6
Pattern constant current
| PFX2512 | PFX2532 |
---|
Range *1 | -50.000 A to 50.000 A | -200.000 A to 200.000 A |
---|
Accuracy *2 | *3 |
---|
Resolution | 1 mA |
---|
Number of settings | 10000 values (Maximum number of steps) |
---|
Time width | Range | 0.1 s to 9999.9 s (Time width for 1 step) |
---|
Accuracy *2 | ±(0.05 % of set + 10 ms) |
---|
Resolution | 100 ms |
---|
Pattern constant power
| PFX2512 | PFX2532 |
---|
Range *1 | -3000.00 W to 3000.00 W | -12000 W to 12000 W |
---|
Accuracy *2 *7 | ±(0.5 % of set + 1 W) *5 | ±(0.5 % of set + 10 W) *5 |
---|
Resolution | 10 mW | 1 W |
---|
Number of settings | 10000 values (Maximum number of steps) |
---|
Time width | Range | 0.1 s to 9999.9 s |
---|
Accuracy *2 | ±(0.05 % of set + 10 ms) |
---|
Resolution | 100 ms |
---|
*1 The range varies depending on factors such as the connected DC power supplies and electronic loads and the wiring configuration of the system. *2 Ambient temperature at 18 °C to 28 °C *3 The external devices are controlled through software so that the measured values are equal to the settings. The accuracy of the settings is the same as the measurement accuracy. Because this is dependent on the control cycle, correct control may not be possible for a DUT (battery) with high impedance or a DUT whose circuit is open. Control cycle for constant current / constant voltage control is 1 ms and for constant cell voltage control is 100 ms. *4 Can be set only when the optional Volt / Thermometer Unit OP02-PFX or OP03-PFX Voltmeter Unit is installed. *5 The battery voltage is measured, and the control current (constant current control) is calculated from the set power value through software calculation. The time required to process one calculation (from the voltage measurement to the output setting) is approximately 1 ms. *6 The operating voltage range is 1 V or more (when the TL10-PFX is being used; regardless of whether a bias DC power supply is being used). *7 With battery voltage of 2 V or more.