0

Setting accuracy

Static

Constant current charge/discharge

PFX2512PFX2532
Range *10.000 A to 50.000 A0.000 A to 200.000 A
Accuracy *2*3
Resolution1 mA

Constant voltage charge/discharge

PFX2512PFX2532
Range *160 V range0.000 V to 60.000 V
6 V range0.000 V to 6.000 V
Accuracy *2*3
Resolution1 mV

Constant cell voltage charge/ discharge *4

PFX2512PFX2532
Range *10.000 A to 20.000 V
Accuracy *2*3
Resolution1 mV

Constant power discharge

PFX2512PFX2532
Range *10.1 W to 3000.0 W1 W to 12000 W
Accuracy *2±(0.5 % of set + 1 W) *5±(0.5 % of set + 10 W) *5
Resolution10 mW1 W

Pattern *6

Pattern constant current

PFX2512PFX2532
Range *1-50.000 A to 50.000 A-200.000 A to 200.000 A
Accuracy *2*3
Resolution1 mA
Number of settings10000 values (Maximum number of steps)
Time widthRange0.1 s to 9999.9 s (Time width for 1 step)
Accuracy *2±(0.05 % of set + 10 ms)
Resolution100 ms

Pattern constant power

PFX2512PFX2532
Range *1-3000.00 W to 3000.00 W-12000 W to 12000 W
Accuracy *2 *7±(0.5 % of set + 1 W) *5±(0.5 % of set + 10 W) *5
Resolution10 mW1 W
Number of settings10000 values (Maximum number of steps)
Time widthRange0.1 s to 9999.9 s
Accuracy *2±(0.05 % of set + 10 ms)
Resolution100 ms

*1 The range varies depending on factors such as the connected DC power supplies and electronic loads and the wiring configuration of the system. *2 Ambient temperature at 18 °C to 28 °C *3 The external devices are controlled through software so that the measured values are equal to the settings. The accuracy of the settings is the same as the measurement accuracy. Because this is dependent on the control cycle, correct control may not be possible for a DUT (battery) with high impedance or a DUT whose circuit is open. Control cycle for constant current / constant voltage control is 1 ms and for constant cell voltage control is 100 ms. *4 Can be set only when the optional Volt / Thermometer Unit OP02-PFX or OP03-PFX Voltmeter Unit is installed. *5 The battery voltage is measured, and the control current (constant current control) is calculated from the set power value through software calculation. The time required to process one calculation (from the voltage measurement to the output setting) is approximately 1 ms. *6 The operating voltage range is 1 V or more (when the TL10-PFX is being used; regardless of whether a bias DC power supply is being used). *7 With battery voltage of 2 V or more.


Related specifications : PFX2500 Series

Please feel free to contact us with any questions or concerns.